SL POWER ELECTRONICS CORP.
6050 King Drive, Bldg. A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com
RATINGS:
Input: 100/120/215/230-240 V ac, 50/60 Hz, Refer to chassis marking for input current ratings.
Output:
Model Output Ratings at 25°C Ambient With Airflow Specified - See Notes Airflow Level Notes
CP197-A+ 5 V 50 A (derate to 44 A at 50 °C) 35 cfm L5 2,4,6
F5-25/OVP-A+ 5 V 25 A 14 cfm L3M1 2,3
F15-15-A+ 12 V 16 A or 15 V 15 A 35 cfm L5 2,3,5
F24-12-A+ 24 V 12 A (derate to 1 0 A at 50 °C) or 28 V 10 A (derate to 8.6 A at 50 °C) 35 cfm L5 2,4,6
F48-6-A+ 48 V 6 A (derate to 5 A at 50 °C) 35 cfm L1 2,4,7
G5-35/OVP-A+ 5 V 35 A 35 cfm L5 2,3,5
HDBB105W-A+ 5 V 12 A; +12 V 1.7 A or +15 V 1.5 A; -12 V 1.7 A or –15 V 1.5 A or 5 V 0.7 A 26 cfm L3M1 2,3
HDCC150W-A+ 5 V 12 A; +12 V 3.4 A or +15 V 3 A; -12 V 3.4 A or –15 V 3 A or –5 V 1.5 A 35 cfm L3M1 2,3
HDD15-5-A+ ±12 V 5 A or ±15 V 5 A 14 cfm L3M1 2,3
HE12-10.2-A+ 12 V 10.2 A 14 cfm L3M1 2,3
HE15-9-A+ 15 V 9 A 14 cfm L3M1 2,3
HE2-18-A+ 2 V 18 A 14 cfm L3M1 2,3
HE24-7.2-A+ 24 V 7.2 A 14 cfm L3M1 2,3
HE28-6-A+ 28 V 6 A 14 cfm L3M1 2,3
HE48-4-A+ 48 V 4 A 14 cfm L1 2,3,8
HE5-18/OVP-A+ 5 V 18 A 14 cfm L3M1 2,3
Notes: 1. Models may be followed by suffix G to indicate compliance to RoHS.
2 Derate output current ratings 1 0 % for operation at 50 Hz.
3. No derating required for operation a t 50 °C ambient unless specified otherwise above.
4. For operation at >25 °C to 50 °C, dera te output linearly to value shown in ta ble.
5. Output capable of exceeding 24 0 VA when overloaded.
6. Output rating exceeds 240 VA.
7. Output exceeds 240 VA and may exceed 60 V dc as a result of a component fa ilure.
8. Output may exceed 6 0 V dc under certain conditions.
9. Maximum Relative Humidity 96 %, no condensation.
10. Storage: -40 °C to +80 °C. Units should be allowed to warm-up under non-condensing conditions before application of power.
SAFETY DECLARATION: SL Power Electronics Corp. declares under our sole responsibility that all
models listed above are in conformity with the applicable requirements of EN 60950-1 following the provisions
of the Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the applicable
requirements of UL 1950, CSA 22.2 No. 234 (see table for level), and EN 60950-1 for Pollution Degree 2
environment and Class I TN-S power systems. The outp ut of some models poses an ener gy hazard or do not meet the
requirements for SELV. To identify these models, r efer to the notes for the table above.
GROUNDING: Protection Class I re quires that the chassis be bonded to Protective Ear th in the end application.
SPACINGS: Creepage and clearance distances from primary circuits to ground and secondary circuits, as defined in the
applicable safety standards, must be maintained after installation to preserve the intended safety.
TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in the applicable safety
standards, must not be exceeded after installatio n to preserve the intended safety. The output power, ambient air temperature
and the availability, amount, directio n and/or restriction of airflow influence the temperatures of these components.
WARNING! RISK OF FIRE! All models require
external fusing to maintain the intended safety. Refer to
marking on chassis for maximum fuse ratings.
AC INPUT HOOKU P
INSTRUCTIONS
41-33496-0001 Rev. G 09/12/06 SHT 1 OF 2
INTERNATIONAL + SERIES
INSTALLATION INSTRUCTIONS
3
5
4
100 VAC
3
5
4
120 VAC
3
5
4
215 VAC
1
2
1
2
1
2
3
5
4
230-240
VAC
1
2
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - INSTALLATION INSTRUCTIONS

SL POWER ELECTRONICS CORP.6050 King Drive, Bldg. AVentura, CA 93003 + 805-486-4565Internet: www.slpower.comRATINGS:Input: 100/120/215/230-240 V ac, 50

Seite 2

FUSING: Internal Secondary fuse(s) are provided on the models listed below A blown internal fuse is an indication ofcatastrophic failure of c ircuit c

Kommentare zu diesen Handbüchern

Keine Kommentare